Education and Safety :: Pump Education :: Articles
Pump Performance Checklist | |
Keeping your pump in shape will help reduce costs and boost profits! Cut fuel consumption, reduce replacement parts costs and minimize pumping time on every job! A PUMP THAT LETS YOU DOWN when you need it most causes obvious losses of time and money. Not so obvious, but every bit as costly, are losses you can incur with pumps that operate at less-than-peak efficiency. A pump laboring under the handicap of a suction line air leak, a corroded discharge line or a clogged impeller uses excessive energy, takes longer than necessary to do the job, and subjects parts to undue stress, causing premature failure. HOW HIGH CAN THE LOSSES RUN? Multiply these possible hidden losses by the number of pumps you have in operation and you see why it pays to keep your pumps in top working order. Gorman-Rupp wants to keep your pumps efficient. But even if you don’t own Gorman-Rupp pumps, you’ll find our 9-point checklist helpful because today every penny of profit counts, and we want your pumps to work as efficiently as possible. CENTRIFUGAL PUMPS There is a noticeable difference in pump flow. Has the discharge flow visibly decreased? Is it taking your pump longer to do the same job than it used to? The slow-up might be caused by a collapsed suction hose lining, a leaking gasket, a plugged suction line, or a damaged or worn impeller or wear plate. Your pump isn’t repriming as rapidly as it once did. Most commonly, slower reprime can be attributed to excessive face clearance. If this is not the cause of your slowdown, check the following: Is the seal leaking? Are all hardware at gaskets tight? Is the suction check valve sealing properly? Is the cutwater section of the volute badly worn? Is the recirculating port clogged? Your pump is making excessive noise. Does it sound like a bunch of marbles rattling in a can? This may be an indication of cavitation and could be caused by a suction lift that’s too high, a suction hose that’s too long or plugged or that has a collapsed lining, a clogged strainer, a combination of any of these, or perhaps a problem on the discharge side of the pump. Failing bearings can also cause excessive noise. Your pump is clogging frequently. The suction check valve may be clogged, the strainer may be too large or too small, face clearance could be too wide, or the strainer may be stuck in mud, plugging the suction side. Your pump is overheating. Very likely the flow of liquid into or out of the pump is being restricted. Improper impeller clearance could be slowing repriming, or the suction strainer may be clogged. USE THIS CHECKLIST TO IMPROVE PUMP PERFORMANCE …AND PROFITS SUCTION LINE
PUMP
DISCHARGE LINE
A WORD ABOUT submersible and diaphragm pumps If your submersible pump is operating at a reduced capacity, it could be caused by a worn impeller, excessive impeller clearance, low or incorrect voltage, or it could be running backward. A discharge head that’s too high, a clogged or kinked hose, or a clogged strainer could also be responsible for reduced flow. Use an amp meter and volt meter to determine if the pump is getting the proper power it needs to operate efficiently. Normal amp readings are provided in the manual accompanying your pump. If your diaphragm pump isn’t pumping as it should, check the diaphragm, suction and discharge check valve flappers and seats, and replace any worn parts. Check suction hose fittings for leaks, and check the plunger rod for proper adjustment. |
<< Back to Education and Safety
Specifications are subject to change. Please contact your Gorman-Rupp Distributor for more details.
The Gorman-Rupp Company Mansfield Division P.O. Box 1217 Mansfield, Ohio 44901-1217, USA Tel: 419-755-1011 Fax: 419-755-1251 E-mail: grsales@gormanrupp.com |
The Gorman-Rupp International Company P.O. Box 1217 Mansfield, Ohio 44901-1217, USA Tel: 419-755-1011 Fax: 419-755-1266 E-mail: intsales@gormanrupp.com |
Gorman-Rupp of Canada, Ltd. 70 Burwell Road St. Thomas, Ontario N5P 3R7, Canada Tel: 519-631-2870 Fax: 519-631-4624 E-mail: grcanada@grcanada.com |
GRpumps.com